With four counting modes, the LUNA-FL™ is our powerhouse. Equipped with brightfield and dual fluorescence optics that allows the sensitive detection of most cell types excluding bacteria. The LUNA-FL™ can distinguish primary cells such as PBMCs, splenocytes, neutrophils, and stem cells from undesirable debris for accurate cell count and viability results. Brightfield cell counting, fluorescence cell counting, yeast cell counting, and GFP transfection assays are all in the LUNA-FL™ wheelhouse. This versatile little counter sits comfortably in a cell culture hood or on your benchtop to fit seamlessly into your workflow.
 


WHAT THE LUNA-FL™ DOES BEST

  • LUNA-FL Dual Fluorescence Cell Counter two counters in one
    TWO COUNTERS IN ONE

    The LUNA-FL™ can count in both brightfield and fluorescence mode, making
    it our most versatile counter to date.

  • LUNA-FL Dual Fluorescence Cell Counter compatible with most cells
    COMPATIBLE WITH MOST CELLS

    Advanced imaging software and GFP and RFP fluorescence optics sensitively
    detect fluorescence stained cells.

  • LUNA-FL Dual Fluorescence Cell Counter gfp transfection analysis
    GFP TRANSFECTION ANALYSIS

    High resolution images are captured and analyzed to detect GFP-positive and -negative cells.

  • LUNA-FL Dual Fluorescence Cell Counter maximum 30 seconds
    MAXIMUM 30 SECONDS

    Fluorescence: 30 s = 3 images captured & analyzed;
    Brightfield: 10 s = 1 image captured & analyzed

THE SOFTWARE THAT CHANGES EVERYTHING.

FOUR COUNTING MODES CUSTOMIZE & SAVE PROTOCOLS USE THE DILUTION CALCULATOR GATE CELLS ON HISTOGRAMS

FOUR COUNTING MODES

THE LOWEST COST. THE GREATEST CONVENIENCE.

Perfect for labs on a budget, our LUNA™ family of automated cell counters work with the LUNA™ Reusable Slide. The LUNA™ Reusable Slide delivers the affordability of manual cell counting without the associated time, subjectivity, and user-to-user variability. Our disposable slides offer the ultimate counting experience. With no mess or cleanup, these precision slides are convenient and maintain the highest standard of cell counting accuracy.
Logos Biosystems LUNA Reusable Slide
Fast automated yeast cell counting algorithm using bright-field and fluorescence microscopic images. Hong D, Lee G, Jung NC, Jeon M. Biological procedures online. 15(1):13.(2013) Antidepressant imipramine diminishes stress-induced inflammation in the periphery and central nervous system and related anxiety- and depressive-like behaviors. Ramirez K, Sheridan JF. Brain, behavior, and immunity. 57:293-303 (2016) High antiviral effects of hibiscus tea extract on the H5 subtypes of low and highly pathogenic avian influenza viruses. Baatarsogt T, Bui VN, Trinh DQ, Yamaguchi E, Gronsang D, Thampsaisarn R, Ogawa H, Imai K. The Journal of veterinary medical science / the Japanese Society of Veterinary Science. 1;78(9):1405-1411. (2016) Minicirclemicroporation-based non-viral gene delivery improved the targeting of mesenchymal stem cells to an injury site. Mun JY, Shin KK, Kwon O, Lim YT, Oh DB. Biomaterials. 101:310-320 (2016) Premedication with clarithromycin is effective against secondary bacterial pneumonia during influenza virus infection in a pulmonary emphysema mouse model. Harada T, Ishimatsu Y, Hara A, Morita T, Nakashima S, Kakugawa T, Sakamoto N, Kosai K, Izumikawa K, Yanagihara K, Mukae H, Kohno S. The Journal of pharmacology and experimental therapeutics. 358(3):457-63. (2016) Broncholaveolar lavage to detect cytomegalovirus infection, latency, and reactivation in immune competent hosts. Mansfield S, Dwivedi V, Byrd S, Trgovcich J, Griessl M, Gutknecht M, Cook C. Journal of medical virology. 88:1408-1416(2016) Harvest tissue source does not alter the protective power of stromal cell therapy following intestinal ischemia and reperfusion injury. Jensen AR, Manning MM, Khaneki S, Drucker NA, Markel TA. The Journal of surgical research. 204:361-370 (2016) In vitro endothelialization test of biomaterials using immortalized endothelial cells. Kono K, Hiruma H, Kobayashi S, Sato Y, Tanaka M, Sawada R, Niimi S. PloS one. 11:e0158289 (2016) High-throughput single-cell derived sphere formation for cancer stem-like cell identification and analysis. Chen YC, Ingram PN, Fouladdel S, McDermott S, Azizi E, Wicha MS, Yoon E. Scientific reports. 6:27301 (2016) Tanshinone IIA induces TRAIL sensitization of human lung cancer cells through selective ER stress induction. Kim EO, Kang SE, Im CR, Lee JH, Ahn KS, Yang WM, Um JY, Lee SG, Yun M. International journal of oncology. 48(5):2205-12. Human induced pluripotent stem cell-derived cardiomyocytes recapitulate the prediction of breast cancer patients to doxorubicin-induced cardiotoxicity. Burridge PW, Li YF, Matsa E, Wu H, Ong SG, Sharma A, Holmström A, Chang AC, Coronado MJ, Ebert AD, Knowles JW, Telli ML, Witteles RM, Blau HM, Berstein D, Altman RB, Wu J. Nature medicine. 22:547-556 (2016) Identification of a small-molecule ligand of the epigenetic reader protein Spindlin1 via a versatile screening platform. Wagner T, Greschik H, Burgahn T, Schmidtkunz K, Schott AK, McMillan J, Baranauskiene L, Xiong Y, Fedorov O, Jin J, Oppermann U, Matulis D, Schüle R, Jung M. Nucleic acids research. 44:e88 (2016) Promotion of cortical neurogenesis from the neural stem cells in the adult mouse subcallosal zone. Kim JY, Choi K, Shaker MR, Lee JH, Lee B, Lee E, Park JY, Lim MS, Park CH, Shin KS, Kim H, Geum D, Sun W. Stem Cells 34(4):888-901 (2016) The relationship between antral follicle count in a bovine ovary and developmental competence of in vitro-grown oocytes derived from early antral follicles. Nagai K, Yanagawa Y, Katagiri S, Nagano M. Biomedical research. 37:63-71 (2016) Local biological effects of adipose stromal vascular fraction delivery systems after subcutaneous implantation in a murine model. Vigani B, Mastracci L, Grillo F, Perteghella S, Preda S, Crivelli B, Antonioli B, Galuzzi M, Tosca MC, Marazzi M, Torre ML, Chlapanidas T. J BioactCompatPolym 2016; doi: 10.1177/0883911516635841 Morusin induces TRAIL Sensitization by regulating EGFR and DR5 in human glioblastoma cells. Park D, Ha IJ, Park SY, Choi M, Lim SL, Kim SH, Lee JH, Ahn KS, Yun M, Lee SG. Journal of natural products. 79:317-323 (2016) Application of a non-hazardous vital dye for cell counting with automated cell counters. Kim SI, Kim HJ, Lee HJ, Lee K, Hong D, Lim H, Cho K, Jung N, Yi YW. Analytical biochemistry,1;492:8-12(2016) Effect of bone morphogenetic protein-4 on in vitro growth, steroidogenesis and subsequent developmental competence of the oocyte-granulosa cell complex derived from bovine early antral follicles. Yang Y, Kanno C, Huang W, Kang SS, Yanagawa Y, Nagano M. Reproductive biology and endocrinology : RB&E. 15;14:3 (2016) Generation of atmospheric-pressure dry- and mist-plasma jets and their effects on HeLa cells. Sonoda T, Umeda K, Wang D, Namihira T, Akiyama H. Plasma Med 2016; 10.1615/PlasmaMed.2016016219 GABAergic modulation with classical benzodiazepines prevent stress-induced neuro-immune dysregulation and behavioral alterations. Ramirez K, Niraula A, Sheridan JF. Brain, behavior, and immunity 51:154-68 (2016) Mouse model for sublethal Leptospira interrogans infection. Richer L, Potula HH, Melo R, Vieira A, Gomes-Solecki M. Infection and immunity. 83(12):4693-700.(2015) Human mesenchymal stromal cells decrease mortality following intestinal ischemia and reperfusion injury. Markel TA, Crafts TD, Jensen AR, Husberger EB, Yoder MC. J The Journal of surgical research. 199(1):56-66.2015; Dual inhibition of EGFR and MET induces synthetic lethality in triple-negative breast cancer cells through downregulation of ribosomal protein S6. Yi YW, You K, Bae EJ, Kwak SJ, Seong YS, Bae I. International journal of oncology. 47(1):122-32 (2015) Expression analyses revealed thymic stromal co-transporter/Slc46A2 is in stem cell populations and is a putative tumor suppressor. Kim KY, Lee G, Yoon M, Cho EH, Park CS, Kim MG. Molecules and cells. 38(6):548-61. (2015) Imipramine attenuates neuroinflammatory signaling and reverses stress-induced social avoidance. Ramirez KG, Shea DT, McKim DB, Reader BF, Sheridan JF. Brain, behavior, and immunity. 46:212-20. Differential regulation of gene expression of alveolar epithelial cell markers in human lung adenocarcinoma-derived A549 clones. Kondo H, Miyoshi K, Sakiyama S, Tangoku A, Noma T. Stem cells international. 2015:165867 (2015) β-TrCP1 degradation is a novel action mechanism of PI3K/mTORC2 inhibitors in triple-negative breast cancer cells. Yi YW, Kang HJ, Bae EJ, Oh S, Soeng YS, Bae I. Experimental & molecular medicine. 47:e143. (2015)
LUNA-FL™: GFP Transfection Assay Quick Start Guide LUNA-FL™ Quick Start Guide LUNA-FL™ Brochure Fast automated yeast cell counting algorithm using bright-field and fluorescence microscopic images Product literature Application of a non-hazardous vital dye for cell counting with automated cell counters GFP expression analysis using the LUNA-FL™ Fast cell counting and viability measurement of yeast cells with the LUNA-FL™ Automated fluorescence cell counting Logos Biosystems Products Brochure LUNA-FL™ software 3.0.1 Software Autoexposure mode update Notice
Compatible Reagents
 
 
 
 
 
 
 

WHAT DO OUR CUSTOMERS HAVE TO SAY?

Testimonials
  • Gelina Sani

    Children's National Medical Center

    The LUNA-FL is one of my favorite machines in our lab. It lets me acquire cell counts so quickly so I can go on with my bench work. Not only are we able to count but we can look at other statistics like viability and average cell size with just the push of a button. The best part about this counter is the accuracy. I am able to reliably count every cell line that I put in, and am able to do it again the next day. I'm so glad we have this system in our lab because counting with trypan blue would take much longer! Overall, I would recommend this product to another lab that is doing a lot of work with cell lines in order to get a quick and accurate count.

  • Mikayla Lopes

    Roger Williams Medical Center

    The LUNA-FL is an extremely easy device to use and very user friendly. With many different modes available, it is certainly a useful tool in the lab. Our service rep is extremely responsive and helpful to our needs and questions. Highly recommend!

  • Regina Wulff, MS

    Weill Cornell Medicine / New York-Presbyterian Hospital

    The LUNA-FL consistently produces fast and reliable results. The counts and viabilities provided by this instrument are consistent with values provided by flow cytometry. This product is remarkably easy to operate, care for, and maintain. In comparison to similar products on the market, the LUNA-FL is exceptional for the low cost.

  • Danh Tran

    Medical University of South Carolina

    Our lab was interested in an automated cell counter because we needed something reproducible enough to compare between groups and to use cell count as a quick approach for normalization. … The LUNA-FL fit our needs the most, and the price was close to our budget. So far, it has been used for many purposes in our lab, including the original assay that we were trying to develop and other applications including quick live/dead information, GFP expression, etc.

  • Woong Sun, PhD

    Korea University Medical School

    I would recommend it simply because it can count a heterogeneous sample obtained from mouse brain. I was surprised by the accuracy of this tiny instrument.

  • May Malicdan, MD PhD

    NIH, NHGRI

    It's very convenient to use and very accurate. Especially in the transfection procedures, it's very helpful. Overall, we're very pleased.

  • Joanna Ireland, PhD

    NIH, NIAID

    It works really well. It's easy. It's accurate and fast. I especially like the dual fluorescence and being able to focus on the green and red cells.

 

WHERE THE LUNA-FL™ HAS BEEN CITED

Citations
  • Thrombin preconditioning of extracellular vesicles derived from mesenchymal stem cells accelerates cutaneous wound healing by boosting their biogenesis and enriching cargo content.
    2019. Sung DK, Chang YS, Sung SI, Ahn SY, Park WS. Journal of Clinical Medicine 8(4): 533.

  • Homotypic and heterotypic trans-assembly of human Rab-family small GTPases in reconstituted membrane tethering.
    2019. Segawa K, Tamura N, Mima J. Journal of Biological Chemistry jbc.RA119.007947.

  • Development of selective cytotoxic viral vectors for concentration of undifferentiated cells in cardiomyocytes derived from human induced pluripotent stem cells.
    2019. Kono K, Sawada R, Kuroda T, Yasuda S, Matsuyama S, Matsuyama A, Mizuguchi H, Sato Y. Scientific Reports 9(1): 3630.

  • Chimeric antigen receptor costimulation domains modulate human regulatory T cell function.
    2019. Boroughs AC, Larson RC, Choi BD, Bouffard AA, Riley LS, Schiferle E, Kulkarni AS, Cetrulo CL, Ting D, Blazar BR, Demehri S, Maus MV. JCI Insight 4(8): e126194.

  • Exploiting evolutionary herding to control drug resistance in cancer.
    2019. Acar A, Nichol D, Fernandez-Mateos J, Cresswell GD, Barozzi I, Hong SP, Spiteri I, Stubbs M, Burke R, Stewart A, Vlachogiannis G, Maley CC, Magnani L, Valeri N, Banerji U, Sottoriva A. bioRxiv 566950.

Resources

Downloads
  • Icon
    LUNA-FL™

    Brochure

    2018-04-18 | 2.1 MB
  • Icon
    Logos Biosystems Products

    Brochure

    2018-04-17 | 2.14 MB
  • Icon
    LUNA-FL™: GFP Transfection Assay

    Quick Start Guide

    2018-04-16 | 110 KB
  • Icon
    LUNA-FL™

    Quick Start Guide

    2018-04-16 | 284 KB
  • Icon
    Fast automated yeast cell counting algorithm using bright-field and fluorescence microscopic images

    Product literature

    2018-04-16 | 1.7 MB
  • Icon
    GFP expression analysis using the LUNA-FL™

    Product literature

    2018-04-16 | 403 MB
  • Icon
    Fast cell counting and viability measurement of yeast cells with the LUNA-FL™

    Product literature

    2018-04-16 | 862 KB
  • Icon
    Automated fluorescence cell counting

    Product literature

    2018-04-16 | 476 KB
  • Icon
    Application of a non-hazardous vital dye for cell counting with automated cell counters

    Product literature

    2018-04-13 | 906 KB
  • Icon
    Using the LUNA Reusable Slide for accurate cell counting with automated cell counters

    Product literature

    2018-04-13 | 665.84 KB
  • Icon
    LUNA-FL™ software 3.0.1

    Software

    2018-04-16 | 3.4 MB
  • Icon
    Autoexposure mode update

    Notice

    2018-04-16 | 2.2 MB
 
 
Cell DB
    • LUNA-FL™ Dual Fluorescence Cell Counter HL-60 50viability
    • HL-60 (50% viability)

      Experimental condition

      HL-60 cells were artificially killed by heating and mixed with healty cells (50:50). Mixed cells were stained with acridine orange-propidium idodide mixture and then counted with the LUNA-FL fluorescence cell counter.

    • HL-60 (high density)

      Experimental condition

      A high density culture of HL-60 cells was counted with the LUNA-FL to verifiy the performance of the instrument. Cells were stained with acridine orange-propidium idodide mixture and then counted. Green and red circle represents viable and dead nucleated cells automatically classified by LUNA-FL.

    • Human peripheral blood

      Human whole blood was collected from a finger tip and diluted in PBS at 1:100. After staining with the AO/PI dyes, white blood cells (WBCs) were counted with the LUNA-FL fluorescence cell counter. Bright field and its corresponding fluorescence image are shown in the left and middle panel, respectively. Area enclosed by the white rectangle is shown in the right panel at high magnification. Note that cells containing nucleic acids (ie., WBCs) were counted and tagged with the green circle. A huge number of red blood cells (RBCs) and platelets seen in the bright field image were not counted by LUNA-FL. No dead WBC was observed in this field of view.

    • Jurkat

      Experimental condition

      Jurkat T cells were stained with acridine orange-propidium idodide mixture and then counted with the LUNA-FL fluorescence cell counter.

show more  +

ORDERING INFORMATION

Cat # Product Qty
L20001 LUNA-FL™ Automated Fluorescence Cell Counter 1 unit
L12005 PhotonSlide™, 50 Slides 1 box
L12006 PhotonSlide™, 500 Slides 10 boxes
L12007 PhotonSlide™, 1000 Slides 20 boxes
L12001 LUNA™ Cell Counting Slides, 50 Slides 1 box
L12002 LUNA™ Cell Counting Slides, 500 Slides 10 boxes
L12003 LUNA™ Cell Counting Slides, 1000 Slides 20 boxes
L12011 LUNA™ Reusable Slide 1 unit
L12012 LUNA™ Reusable Slides 2 units
L12014 LUNA™ Reusable Slide Coverslips 10 units
T13001 Trypan Blue Stain, 0.4% 2 X 1 mL
L13002 Erythrosin B Stain 2 x 1 mL
F23001 Acridine Orange/Propidium Iodide Stain 2 x 0.5 mL
F23002 Acridine Orange Stain 2 x 0.5 mL
F23003 Yeast Viability Kit 1
- Propidium Iodide Stain for Yeast (1 x 0.5 mL)
- Fluorescein Diacetate Stain (1 x 0.5 mL)
- Cell Dilution Buffer (1 x 20 mL)
- Fluorescence Signal Enhancer 1 (1 x 0.5 mL)
1 kit
F23212 Cell Dilution Buffer 5 x 20 mL
F23102 LUNA™ Fluorescence Calibration Beads 1 x 0.5 mL
B13101 LUNA™ Standard Beads 2 x 1 mL
F24003 LUNA-FL™ IQ/OQ Protocol 1 copy
P10001 LUNA™ Printer 1 unit
P10002 LUNA™ Printer Paper - thermal, 700 prints 3 x 2 rolls
LUNA-FL™ Dual Fluorescence Cell Counter (L20001) LogosBio
LUNA-FL™ Dual Fluorescence Cell Counter (L20001) LogosBio
With four counting modes, the LUNA-FL™ is our powerhouse. Equipped with brightfield and dual fluorescence optics that allows the sensitive detection of most cell types excluding bacteria. The LUNA-FL™ can distinguish primary cells such as PBMCs, splenocytes, neutrophils, and stem cells from undesirable debris for accurate cell count and viability results. Brightfield cell counting, fluorescence cell counting, yeast cell counting, and GFP transfection assays are all in the LUNA-FL™ wheelhouse. This versatile little counter sits comfortably in a cell culture hood or on your benchtop to fit seamlessly into your workflow.
 


WHAT THE LUNA-FL™ DOES BEST

  • LUNA-FL Dual Fluorescence Cell Counter two counters in one
    TWO COUNTERS IN ONE

    The LUNA-FL™ can count in both brightfield and fluorescence mode, making
    it our most versatile counter to date.

  • LUNA-FL Dual Fluorescence Cell Counter compatible with most cells
    COMPATIBLE WITH MOST CELLS

    Advanced imaging software and GFP and RFP fluorescence optics sensitively
    detect fluorescence stained cells.

  • LUNA-FL Dual Fluorescence Cell Counter gfp transfection analysis
    GFP TRANSFECTION ANALYSIS

    High resolution images are captured and analyzed to detect GFP-positive and -negative cells.

  • LUNA-FL Dual Fluorescence Cell Counter maximum 30 seconds
    MAXIMUM 30 SECONDS

    Fluorescence: 30 s = 3 images captured & analyzed;
    Brightfield: 10 s = 1 image captured & analyzed

THE SOFTWARE THAT CHANGES EVERYTHING.

FOUR COUNTING MODES CUSTOMIZE & SAVE PROTOCOLS USE THE DILUTION CALCULATOR GATE CELLS ON HISTOGRAMS

FOUR COUNTING MODES

THE LOWEST COST. THE GREATEST CONVENIENCE.

Perfect for labs on a budget, our LUNA™ family of automated cell counters work with the LUNA™ Reusable Slide. The LUNA™ Reusable Slide delivers the affordability of manual cell counting without the associated time, subjectivity, and user-to-user variability. Our disposable slides offer the ultimate counting experience. With no mess or cleanup, these precision slides are convenient and maintain the highest standard of cell counting accuracy.
Logos Biosystems LUNA Reusable Slide
Fast automated yeast cell counting algorithm using bright-field and fluorescence microscopic images. Hong D, Lee G, Jung NC, Jeon M. Biological procedures online. 15(1):13.(2013) Antidepressant imipramine diminishes stress-induced inflammation in the periphery and central nervous system and related anxiety- and depressive-like behaviors. Ramirez K, Sheridan JF. Brain, behavior, and immunity. 57:293-303 (2016) High antiviral effects of hibiscus tea extract on the H5 subtypes of low and highly pathogenic avian influenza viruses. Baatarsogt T, Bui VN, Trinh DQ, Yamaguchi E, Gronsang D, Thampsaisarn R, Ogawa H, Imai K. The Journal of veterinary medical science / the Japanese Society of Veterinary Science. 1;78(9):1405-1411. (2016) Minicirclemicroporation-based non-viral gene delivery improved the targeting of mesenchymal stem cells to an injury site. Mun JY, Shin KK, Kwon O, Lim YT, Oh DB. Biomaterials. 101:310-320 (2016) Premedication with clarithromycin is effective against secondary bacterial pneumonia during influenza virus infection in a pulmonary emphysema mouse model. Harada T, Ishimatsu Y, Hara A, Morita T, Nakashima S, Kakugawa T, Sakamoto N, Kosai K, Izumikawa K, Yanagihara K, Mukae H, Kohno S. The Journal of pharmacology and experimental therapeutics. 358(3):457-63. (2016) Broncholaveolar lavage to detect cytomegalovirus infection, latency, and reactivation in immune competent hosts. Mansfield S, Dwivedi V, Byrd S, Trgovcich J, Griessl M, Gutknecht M, Cook C. Journal of medical virology. 88:1408-1416(2016) Harvest tissue source does not alter the protective power of stromal cell therapy following intestinal ischemia and reperfusion injury. Jensen AR, Manning MM, Khaneki S, Drucker NA, Markel TA. The Journal of surgical research. 204:361-370 (2016) In vitro endothelialization test of biomaterials using immortalized endothelial cells. Kono K, Hiruma H, Kobayashi S, Sato Y, Tanaka M, Sawada R, Niimi S. PloS one. 11:e0158289 (2016) High-throughput single-cell derived sphere formation for cancer stem-like cell identification and analysis. Chen YC, Ingram PN, Fouladdel S, McDermott S, Azizi E, Wicha MS, Yoon E. Scientific reports. 6:27301 (2016) Tanshinone IIA induces TRAIL sensitization of human lung cancer cells through selective ER stress induction. Kim EO, Kang SE, Im CR, Lee JH, Ahn KS, Yang WM, Um JY, Lee SG, Yun M. International journal of oncology. 48(5):2205-12. Human induced pluripotent stem cell-derived cardiomyocytes recapitulate the prediction of breast cancer patients to doxorubicin-induced cardiotoxicity. Burridge PW, Li YF, Matsa E, Wu H, Ong SG, Sharma A, Holmström A, Chang AC, Coronado MJ, Ebert AD, Knowles JW, Telli ML, Witteles RM, Blau HM, Berstein D, Altman RB, Wu J. Nature medicine. 22:547-556 (2016) Identification of a small-molecule ligand of the epigenetic reader protein Spindlin1 via a versatile screening platform. Wagner T, Greschik H, Burgahn T, Schmidtkunz K, Schott AK, McMillan J, Baranauskiene L, Xiong Y, Fedorov O, Jin J, Oppermann U, Matulis D, Schüle R, Jung M. Nucleic acids research. 44:e88 (2016) Promotion of cortical neurogenesis from the neural stem cells in the adult mouse subcallosal zone. Kim JY, Choi K, Shaker MR, Lee JH, Lee B, Lee E, Park JY, Lim MS, Park CH, Shin KS, Kim H, Geum D, Sun W. Stem Cells 34(4):888-901 (2016) The relationship between antral follicle count in a bovine ovary and developmental competence of in vitro-grown oocytes derived from early antral follicles. Nagai K, Yanagawa Y, Katagiri S, Nagano M. Biomedical research. 37:63-71 (2016) Local biological effects of adipose stromal vascular fraction delivery systems after subcutaneous implantation in a murine model. Vigani B, Mastracci L, Grillo F, Perteghella S, Preda S, Crivelli B, Antonioli B, Galuzzi M, Tosca MC, Marazzi M, Torre ML, Chlapanidas T. J BioactCompatPolym 2016; doi: 10.1177/0883911516635841 Morusin induces TRAIL Sensitization by regulating EGFR and DR5 in human glioblastoma cells. Park D, Ha IJ, Park SY, Choi M, Lim SL, Kim SH, Lee JH, Ahn KS, Yun M, Lee SG. Journal of natural products. 79:317-323 (2016) Application of a non-hazardous vital dye for cell counting with automated cell counters. Kim SI, Kim HJ, Lee HJ, Lee K, Hong D, Lim H, Cho K, Jung N, Yi YW. Analytical biochemistry,1;492:8-12(2016) Effect of bone morphogenetic protein-4 on in vitro growth, steroidogenesis and subsequent developmental competence of the oocyte-granulosa cell complex derived from bovine early antral follicles. Yang Y, Kanno C, Huang W, Kang SS, Yanagawa Y, Nagano M. Reproductive biology and endocrinology : RB&E. 15;14:3 (2016) Generation of atmospheric-pressure dry- and mist-plasma jets and their effects on HeLa cells. Sonoda T, Umeda K, Wang D, Namihira T, Akiyama H. Plasma Med 2016; 10.1615/PlasmaMed.2016016219 GABAergic modulation with classical benzodiazepines prevent stress-induced neuro-immune dysregulation and behavioral alterations. Ramirez K, Niraula A, Sheridan JF. Brain, behavior, and immunity 51:154-68 (2016) Mouse model for sublethal Leptospira interrogans infection. Richer L, Potula HH, Melo R, Vieira A, Gomes-Solecki M. Infection and immunity. 83(12):4693-700.(2015) Human mesenchymal stromal cells decrease mortality following intestinal ischemia and reperfusion injury. Markel TA, Crafts TD, Jensen AR, Husberger EB, Yoder MC. J The Journal of surgical research. 199(1):56-66.2015; Dual inhibition of EGFR and MET induces synthetic lethality in triple-negative breast cancer cells through downregulation of ribosomal protein S6. Yi YW, You K, Bae EJ, Kwak SJ, Seong YS, Bae I. International journal of oncology. 47(1):122-32 (2015) Expression analyses revealed thymic stromal co-transporter/Slc46A2 is in stem cell populations and is a putative tumor suppressor. Kim KY, Lee G, Yoon M, Cho EH, Park CS, Kim MG. Molecules and cells. 38(6):548-61. (2015) Imipramine attenuates neuroinflammatory signaling and reverses stress-induced social avoidance. Ramirez KG, Shea DT, McKim DB, Reader BF, Sheridan JF. Brain, behavior, and immunity. 46:212-20. Differential regulation of gene expression of alveolar epithelial cell markers in human lung adenocarcinoma-derived A549 clones. Kondo H, Miyoshi K, Sakiyama S, Tangoku A, Noma T. Stem cells international. 2015:165867 (2015) β-TrCP1 degradation is a novel action mechanism of PI3K/mTORC2 inhibitors in triple-negative breast cancer cells. Yi YW, Kang HJ, Bae EJ, Oh S, Soeng YS, Bae I. Experimental & molecular medicine. 47:e143. (2015)
LUNA-FL™: GFP Transfection Assay Quick Start Guide LUNA-FL™ Quick Start Guide LUNA-FL™ Brochure Fast automated yeast cell counting algorithm using bright-field and fluorescence microscopic images Product literature Application of a non-hazardous vital dye for cell counting with automated cell counters GFP expression analysis using the LUNA-FL™ Fast cell counting and viability measurement of yeast cells with the LUNA-FL™ Automated fluorescence cell counting Logos Biosystems Products Brochure LUNA-FL™ software 3.0.1 Software Autoexposure mode update Notice
Compatible Reagents
 
 
 
 
 
 
 

WHAT DO OUR CUSTOMERS HAVE TO SAY?

Testimonials
  • Gelina Sani

    Children's National Medical Center

    The LUNA-FL is one of my favorite machines in our lab. It lets me acquire cell counts so quickly so I can go on with my bench work. Not only are we able to count but we can look at other statistics like viability and average cell size with just the push of a button. The best part about this counter is the accuracy. I am able to reliably count every cell line that I put in, and am able to do it again the next day. I'm so glad we have this system in our lab because counting with trypan blue would take much longer! Overall, I would recommend this product to another lab that is doing a lot of work with cell lines in order to get a quick and accurate count.

  • Mikayla Lopes

    Roger Williams Medical Center

    The LUNA-FL is an extremely easy device to use and very user friendly. With many different modes available, it is certainly a useful tool in the lab. Our service rep is extremely responsive and helpful to our needs and questions. Highly recommend!

  • Regina Wulff, MS

    Weill Cornell Medicine / New York-Presbyterian Hospital

    The LUNA-FL consistently produces fast and reliable results. The counts and viabilities provided by this instrument are consistent with values provided by flow cytometry. This product is remarkably easy to operate, care for, and maintain. In comparison to similar products on the market, the LUNA-FL is exceptional for the low cost.

  • Danh Tran

    Medical University of South Carolina

    Our lab was interested in an automated cell counter because we needed something reproducible enough to compare between groups and to use cell count as a quick approach for normalization. … The LUNA-FL fit our needs the most, and the price was close to our budget. So far, it has been used for many purposes in our lab, including the original assay that we were trying to develop and other applications including quick live/dead information, GFP expression, etc.

  • Woong Sun, PhD

    Korea University Medical School

    I would recommend it simply because it can count a heterogeneous sample obtained from mouse brain. I was surprised by the accuracy of this tiny instrument.

  • May Malicdan, MD PhD

    NIH, NHGRI

    It's very convenient to use and very accurate. Especially in the transfection procedures, it's very helpful. Overall, we're very pleased.

  • Joanna Ireland, PhD

    NIH, NIAID

    It works really well. It's easy. It's accurate and fast. I especially like the dual fluorescence and being able to focus on the green and red cells.

 

WHERE THE LUNA-FL™ HAS BEEN CITED

Citations
  • Thrombin preconditioning of extracellular vesicles derived from mesenchymal stem cells accelerates cutaneous wound healing by boosting their biogenesis and enriching cargo content.
    2019. Sung DK, Chang YS, Sung SI, Ahn SY, Park WS. Journal of Clinical Medicine 8(4): 533.

  • Homotypic and heterotypic trans-assembly of human Rab-family small GTPases in reconstituted membrane tethering.
    2019. Segawa K, Tamura N, Mima J. Journal of Biological Chemistry jbc.RA119.007947.

  • Development of selective cytotoxic viral vectors for concentration of undifferentiated cells in cardiomyocytes derived from human induced pluripotent stem cells.
    2019. Kono K, Sawada R, Kuroda T, Yasuda S, Matsuyama S, Matsuyama A, Mizuguchi H, Sato Y. Scientific Reports 9(1): 3630.

  • Chimeric antigen receptor costimulation domains modulate human regulatory T cell function.
    2019. Boroughs AC, Larson RC, Choi BD, Bouffard AA, Riley LS, Schiferle E, Kulkarni AS, Cetrulo CL, Ting D, Blazar BR, Demehri S, Maus MV. JCI Insight 4(8): e126194.

  • Exploiting evolutionary herding to control drug resistance in cancer.
    2019. Acar A, Nichol D, Fernandez-Mateos J, Cresswell GD, Barozzi I, Hong SP, Spiteri I, Stubbs M, Burke R, Stewart A, Vlachogiannis G, Maley CC, Magnani L, Valeri N, Banerji U, Sottoriva A. bioRxiv 566950.

Resources

Downloads
  • Icon
    LUNA-FL™

    Brochure

    2018-04-18 | 2.1 MB
  • Icon
    Logos Biosystems Products

    Brochure

    2018-04-17 | 2.14 MB
  • Icon
    LUNA-FL™: GFP Transfection Assay

    Quick Start Guide

    2018-04-16 | 110 KB
  • Icon
    LUNA-FL™

    Quick Start Guide

    2018-04-16 | 284 KB
  • Icon
    Fast automated yeast cell counting algorithm using bright-field and fluorescence microscopic images

    Product literature

    2018-04-16 | 1.7 MB
  • Icon
    GFP expression analysis using the LUNA-FL™

    Product literature

    2018-04-16 | 403 MB
  • Icon
    Fast cell counting and viability measurement of yeast cells with the LUNA-FL™

    Product literature

    2018-04-16 | 862 KB
  • Icon
    Automated fluorescence cell counting

    Product literature

    2018-04-16 | 476 KB
  • Icon
    Application of a non-hazardous vital dye for cell counting with automated cell counters

    Product literature

    2018-04-13 | 906 KB
  • Icon
    Using the LUNA Reusable Slide for accurate cell counting with automated cell counters

    Product literature

    2018-04-13 | 665.84 KB
  • Icon
    LUNA-FL™ software 3.0.1

    Software

    2018-04-16 | 3.4 MB
  • Icon
    Autoexposure mode update

    Notice

    2018-04-16 | 2.2 MB
 
 
Cell DB
    • LUNA-FL™ Dual Fluorescence Cell Counter HL-60 50viability
    • HL-60 (50% viability)

      Experimental condition

      HL-60 cells were artificially killed by heating and mixed with healty cells (50:50). Mixed cells were stained with acridine orange-propidium idodide mixture and then counted with the LUNA-FL fluorescence cell counter.

    • HL-60 (high density)

      Experimental condition

      A high density culture of HL-60 cells was counted with the LUNA-FL to verifiy the performance of the instrument. Cells were stained with acridine orange-propidium idodide mixture and then counted. Green and red circle represents viable and dead nucleated cells automatically classified by LUNA-FL.

    • Human peripheral blood

      Human whole blood was collected from a finger tip and diluted in PBS at 1:100. After staining with the AO/PI dyes, white blood cells (WBCs) were counted with the LUNA-FL fluorescence cell counter. Bright field and its corresponding fluorescence image are shown in the left and middle panel, respectively. Area enclosed by the white rectangle is shown in the right panel at high magnification. Note that cells containing nucleic acids (ie., WBCs) were counted and tagged with the green circle. A huge number of red blood cells (RBCs) and platelets seen in the bright field image were not counted by LUNA-FL. No dead WBC was observed in this field of view.

    • Jurkat

      Experimental condition

      Jurkat T cells were stained with acridine orange-propidium idodide mixture and then counted with the LUNA-FL fluorescence cell counter.

show more  +

ORDERING INFORMATION

Cat # Product Qty
L20001 LUNA-FL™ Automated Fluorescence Cell Counter 1 unit
L12005 PhotonSlide™, 50 Slides 1 box
L12006 PhotonSlide™, 500 Slides 10 boxes
L12007 PhotonSlide™, 1000 Slides 20 boxes
L12001 LUNA™ Cell Counting Slides, 50 Slides 1 box
L12002 LUNA™ Cell Counting Slides, 500 Slides 10 boxes
L12003 LUNA™ Cell Counting Slides, 1000 Slides 20 boxes
L12011 LUNA™ Reusable Slide 1 unit
L12012 LUNA™ Reusable Slides 2 units
L12014 LUNA™ Reusable Slide Coverslips 10 units
T13001 Trypan Blue Stain, 0.4% 2 X 1 mL
L13002 Erythrosin B Stain 2 x 1 mL
F23001 Acridine Orange/Propidium Iodide Stain 2 x 0.5 mL
F23002 Acridine Orange Stain 2 x 0.5 mL
F23003 Yeast Viability Kit 1
- Propidium Iodide Stain for Yeast (1 x 0.5 mL)
- Fluorescein Diacetate Stain (1 x 0.5 mL)
- Cell Dilution Buffer (1 x 20 mL)
- Fluorescence Signal Enhancer 1 (1 x 0.5 mL)
1 kit
F23212 Cell Dilution Buffer 5 x 20 mL
F23102 LUNA™ Fluorescence Calibration Beads 1 x 0.5 mL
B13101 LUNA™ Standard Beads 2 x 1 mL
F24003 LUNA-FL™ IQ/OQ Protocol 1 copy
P10001 LUNA™ Printer 1 unit
P10002 LUNA™ Printer Paper - thermal, 700 prints 3 x 2 rolls